NMR Spectroscopy
Welcome to the Solution State NMR Facility Website
If you are new here, please read this page and you will find important information and answers to some of the questions you may have.
Current users can find useful updates.
The NMR instruments are located in A109, A110, A111B and MAS 1.08
- Safety Rules
- Open Access Training Request
- Job Submission
- High Field NMR Schedule
- High Field NMR Booking
- Feedback
For use of Open Access NMR spectrometers, please follow this link
Open Access Instruments (A110, A111B)
If you wish to use the following instruments, you have to apply for a training session run by the NMR staff before access to these instruments will be granted.
HD300 |
Bruker Avance III HD 300 MHz |
1H, 13C, 19F, 31P, 11B 1-Dimensional and 2-Dimensional experiments |
HD400 |
Bruker Avance III HD 400 MHz |
1H, 13C, 19F, 31P 1-Dimensional and 2-Dimensional experiments |
AV400 |
Bruker Avance III 400 MHz |
1H, 13C, 19F, 31P 1-Dimensional and 2-Dimensional experiments |
NEO400 |
Bruker Avance NEO 400 MHz |
1H, 13C, 19F, 31P 1-Dimensional, 2-Dimensional experiments, kinetics and variable temperature studies |
High Field Instruments (A109 and MAS 1.08)
These following instruments are operated by NMR Facility staff and select advance/highly trained users.
You can request service work on a high field instrument, but please consult NMR Facility Staff beforehand.
HD500 |
Bruker Avance III HD 500 MHz | Instrument is set up to run majority of 13C experiments |
AV500 |
Bruker Avance 500 MHz |
Instruments are able to run wide range of 1-Dimensional and 2-Dimensional experiments (including variable temperature, non-standard experiments, unusual nuclei, NOE/GOESY type experiments etc.) |
AV600 |
Bruker Avance III 600 MHz |
NEO700 |
Bruker Avance NEO 700 MHz |
equipped with TCI (including the 19F capability) and TXO cryoprpobes (1H, 13C, 15N, 19F 1-Dimensional and 2-Dimensional experiments and triple resonance experiments for proteins) |
If you publish results using data obtained on this spectrometer with the updated console please include the following sentence in your acknowledgement: "The renewal of the 700 MHz NMR console (Avance NEO), TCI and TXO cryoprobes was funded by BBSRC (Grant No. BB/W020297/1) and University of Warwick" |
Office and Lab Hours
Monday-Friday
08:00 to 16:00
Contact:
Dr. Ivan Prokes
NMR Facility Manager and Assistant Professor (Research Focussed)
Room: A107
Mobile: 07920 531123
E-mail: I.Prokes(@warwick.ac.uk)
Mr Robert Perry
Senior NMR Spectroscopy Technician
Room: A107
E-mail: R.Perry.1(@warwick.ac.uk)
Useful Links
NMR usage regulationsLink opens in a new window
Updated version of NMR usage regulations - Best practiceLink opens in a new window